A Clinical and Radiographic Evaluation of Zirconia Dental Implants: 10-Year Follow-Up
Purpose. The aim is to evaluate the survival and success rates, as well as the marginal bone loss (MBL) and periodontal indexes, of zirconia implants with 10-year follow-up. Materials and Methods. 10 patients were selected and 26 one-piece zirconia implants were used for the rehabilitation of single...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2021-01-01
|
Series: | International Journal of Dentistry |
Online Access: | http://dx.doi.org/10.1155/2021/7534607 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832566387503005696 |
---|---|
author | Andrea Enrico Borgonovo Susanna Ferrario Carlo Maiorana Virna Vavassori Rachele Censi Dino Re |
author_facet | Andrea Enrico Borgonovo Susanna Ferrario Carlo Maiorana Virna Vavassori Rachele Censi Dino Re |
author_sort | Andrea Enrico Borgonovo |
collection | DOAJ |
description | Purpose. The aim is to evaluate the survival and success rates, as well as the marginal bone loss (MBL) and periodontal indexes, of zirconia implants with 10-year follow-up. Materials and Methods. 10 patients were selected and 26 one-piece zirconia implants were used for the rehabilitation of single tooth or partially edentulous ridge. After 10 years, a clinical-radiographic evaluation was performed in order to estimate peri-implant tissue health and marginal bone loss. Results. The survival and success rates were 100%. The average marginal bone loss from baseline to 120 months after surgery was 0.92 ± 0.97 mm. Conclusion. One-piece zirconia dental implants are characterised by high biocompatibility, low plaque adhesion, and absence of microgap that can be related to the clinical success of these implants. |
format | Article |
id | doaj-art-0f2a9ccbcc56471d86e63f0a92e8a55b |
institution | Kabale University |
issn | 1687-8736 |
language | English |
publishDate | 2021-01-01 |
publisher | Wiley |
record_format | Article |
series | International Journal of Dentistry |
spelling | doaj-art-0f2a9ccbcc56471d86e63f0a92e8a55b2025-02-03T01:04:16ZengWileyInternational Journal of Dentistry1687-87362021-01-01202110.1155/2021/7534607A Clinical and Radiographic Evaluation of Zirconia Dental Implants: 10-Year Follow-UpAndrea Enrico Borgonovo0Susanna Ferrario1Carlo Maiorana2Virna Vavassori3Rachele Censi4Dino Re5Department of Esthetic DentistryFondazione IRCCS Ca’ Granda Ospedale Maggiore PoliclinicoHead Department of Implant Center for Edentulism and Jawbone AtrophiesDepartment of Esthetic DentistryDepartment of Esthetic DentistryHead Department of Esthetic DentistryPurpose. The aim is to evaluate the survival and success rates, as well as the marginal bone loss (MBL) and periodontal indexes, of zirconia implants with 10-year follow-up. Materials and Methods. 10 patients were selected and 26 one-piece zirconia implants were used for the rehabilitation of single tooth or partially edentulous ridge. After 10 years, a clinical-radiographic evaluation was performed in order to estimate peri-implant tissue health and marginal bone loss. Results. The survival and success rates were 100%. The average marginal bone loss from baseline to 120 months after surgery was 0.92 ± 0.97 mm. Conclusion. One-piece zirconia dental implants are characterised by high biocompatibility, low plaque adhesion, and absence of microgap that can be related to the clinical success of these implants.http://dx.doi.org/10.1155/2021/7534607 |
spellingShingle | Andrea Enrico Borgonovo Susanna Ferrario Carlo Maiorana Virna Vavassori Rachele Censi Dino Re A Clinical and Radiographic Evaluation of Zirconia Dental Implants: 10-Year Follow-Up International Journal of Dentistry |
title | A Clinical and Radiographic Evaluation of Zirconia Dental Implants: 10-Year Follow-Up |
title_full | A Clinical and Radiographic Evaluation of Zirconia Dental Implants: 10-Year Follow-Up |
title_fullStr | A Clinical and Radiographic Evaluation of Zirconia Dental Implants: 10-Year Follow-Up |
title_full_unstemmed | A Clinical and Radiographic Evaluation of Zirconia Dental Implants: 10-Year Follow-Up |
title_short | A Clinical and Radiographic Evaluation of Zirconia Dental Implants: 10-Year Follow-Up |
title_sort | clinical and radiographic evaluation of zirconia dental implants 10 year follow up |
url | http://dx.doi.org/10.1155/2021/7534607 |
work_keys_str_mv | AT andreaenricoborgonovo aclinicalandradiographicevaluationofzirconiadentalimplants10yearfollowup AT susannaferrario aclinicalandradiographicevaluationofzirconiadentalimplants10yearfollowup AT carlomaiorana aclinicalandradiographicevaluationofzirconiadentalimplants10yearfollowup AT virnavavassori aclinicalandradiographicevaluationofzirconiadentalimplants10yearfollowup AT rachelecensi aclinicalandradiographicevaluationofzirconiadentalimplants10yearfollowup AT dinore aclinicalandradiographicevaluationofzirconiadentalimplants10yearfollowup AT andreaenricoborgonovo clinicalandradiographicevaluationofzirconiadentalimplants10yearfollowup AT susannaferrario clinicalandradiographicevaluationofzirconiadentalimplants10yearfollowup AT carlomaiorana clinicalandradiographicevaluationofzirconiadentalimplants10yearfollowup AT virnavavassori clinicalandradiographicevaluationofzirconiadentalimplants10yearfollowup AT rachelecensi clinicalandradiographicevaluationofzirconiadentalimplants10yearfollowup AT dinore clinicalandradiographicevaluationofzirconiadentalimplants10yearfollowup |