A Comparative Biomechanical Analysis of the Impact of Different Configurations of Pedicle-Screw-Based Fixation in Thoracolumbar Compression Fracture

The aim of this experimental study was to analyze the impact of applying different configurations of the transpedicular fixation system on selected mechanical parameters of the thoracolumbar spine under conditions of its instability (after simulated fracture). Five study groups were tested: physiolo...

Full description

Saved in:
Bibliographic Details
Main Authors: Klaudia Szkoda-Poliszuk, Rafał Załuski
Format: Article
Language:English
Published: Wiley 2022-01-01
Series:Applied Bionics and Biomechanics
Online Access:http://dx.doi.org/10.1155/2022/3817097
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832567984117252096
author Klaudia Szkoda-Poliszuk
Rafał Załuski
author_facet Klaudia Szkoda-Poliszuk
Rafał Załuski
author_sort Klaudia Szkoda-Poliszuk
collection DOAJ
description The aim of this experimental study was to analyze the impact of applying different configurations of the transpedicular fixation system on selected mechanical parameters of the thoracolumbar spine under conditions of its instability (after simulated fracture). Five study groups were tested: physiological, with compression fracture of the vertebra, with two-segment fixation, with three-segment fixation, and with four-segment fixation. Each of the analyzed study groups was subjected to axial compression, flexion, and extension. Based on the conducted experimental tests, the mechanical parameters, i.e., stiffness coefficient and dissipation energy, were determined for all groups under consideration. The stiffness value of two-segment fixation is significantly lower than the physiological value (during flexion and extension). The use of long-segment fixation considered in two configurations (three- and four-segment fixation) may result in excessive stiffness of the system due to the high stiffness values achieved (approx. 25–30% higher than the physiological values in the case of compression and on average 60% higher in the case of flexion). The use of long-segment fixator design shows better results than short-segment fixation. Considering both biomechanical and clinical aspects, three-segment fixation seems to be a compromise solution as it saves the patient from more extensive stiffening of the spinal motion segments.
format Article
id doaj-art-0f1e72f31b3f46b091cd3b9d2ac85711
institution Kabale University
issn 1754-2103
language English
publishDate 2022-01-01
publisher Wiley
record_format Article
series Applied Bionics and Biomechanics
spelling doaj-art-0f1e72f31b3f46b091cd3b9d2ac857112025-02-03T00:59:54ZengWileyApplied Bionics and Biomechanics1754-21032022-01-01202210.1155/2022/3817097A Comparative Biomechanical Analysis of the Impact of Different Configurations of Pedicle-Screw-Based Fixation in Thoracolumbar Compression FractureKlaudia Szkoda-Poliszuk0Rafał Załuski1Department of MechanicsDepartment of NeurosurgeryThe aim of this experimental study was to analyze the impact of applying different configurations of the transpedicular fixation system on selected mechanical parameters of the thoracolumbar spine under conditions of its instability (after simulated fracture). Five study groups were tested: physiological, with compression fracture of the vertebra, with two-segment fixation, with three-segment fixation, and with four-segment fixation. Each of the analyzed study groups was subjected to axial compression, flexion, and extension. Based on the conducted experimental tests, the mechanical parameters, i.e., stiffness coefficient and dissipation energy, were determined for all groups under consideration. The stiffness value of two-segment fixation is significantly lower than the physiological value (during flexion and extension). The use of long-segment fixation considered in two configurations (three- and four-segment fixation) may result in excessive stiffness of the system due to the high stiffness values achieved (approx. 25–30% higher than the physiological values in the case of compression and on average 60% higher in the case of flexion). The use of long-segment fixator design shows better results than short-segment fixation. Considering both biomechanical and clinical aspects, three-segment fixation seems to be a compromise solution as it saves the patient from more extensive stiffening of the spinal motion segments.http://dx.doi.org/10.1155/2022/3817097
spellingShingle Klaudia Szkoda-Poliszuk
Rafał Załuski
A Comparative Biomechanical Analysis of the Impact of Different Configurations of Pedicle-Screw-Based Fixation in Thoracolumbar Compression Fracture
Applied Bionics and Biomechanics
title A Comparative Biomechanical Analysis of the Impact of Different Configurations of Pedicle-Screw-Based Fixation in Thoracolumbar Compression Fracture
title_full A Comparative Biomechanical Analysis of the Impact of Different Configurations of Pedicle-Screw-Based Fixation in Thoracolumbar Compression Fracture
title_fullStr A Comparative Biomechanical Analysis of the Impact of Different Configurations of Pedicle-Screw-Based Fixation in Thoracolumbar Compression Fracture
title_full_unstemmed A Comparative Biomechanical Analysis of the Impact of Different Configurations of Pedicle-Screw-Based Fixation in Thoracolumbar Compression Fracture
title_short A Comparative Biomechanical Analysis of the Impact of Different Configurations of Pedicle-Screw-Based Fixation in Thoracolumbar Compression Fracture
title_sort comparative biomechanical analysis of the impact of different configurations of pedicle screw based fixation in thoracolumbar compression fracture
url http://dx.doi.org/10.1155/2022/3817097
work_keys_str_mv AT klaudiaszkodapoliszuk acomparativebiomechanicalanalysisoftheimpactofdifferentconfigurationsofpediclescrewbasedfixationinthoracolumbarcompressionfracture
AT rafałzałuski acomparativebiomechanicalanalysisoftheimpactofdifferentconfigurationsofpediclescrewbasedfixationinthoracolumbarcompressionfracture
AT klaudiaszkodapoliszuk comparativebiomechanicalanalysisoftheimpactofdifferentconfigurationsofpediclescrewbasedfixationinthoracolumbarcompressionfracture
AT rafałzałuski comparativebiomechanicalanalysisoftheimpactofdifferentconfigurationsofpediclescrewbasedfixationinthoracolumbarcompressionfracture