Highly sensitive non-enzymatic glucose sensing using Ni nanowires and graphene thin film on the gate area of extended gate electric double-layer field-effect transistor

This study presents an innovative glucose detection platform, featuring a highly sensitive, non-enzymatic glucose sensor. The sensor integrates nickel nanowires and a graphene thin film deposited on the gate region of an extended-gate electric double-layer field-effect transistor (EGEDL-FET). This u...

Full description

Saved in:
Bibliographic Details
Main Author: Sheng-Chun Hung
Format: Article
Language:English
Published: Elsevier 2025-01-01
Series:Heliyon
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2405844025002373
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832573125311594496
author Sheng-Chun Hung
author_facet Sheng-Chun Hung
author_sort Sheng-Chun Hung
collection DOAJ
description This study presents an innovative glucose detection platform, featuring a highly sensitive, non-enzymatic glucose sensor. The sensor integrates nickel nanowires and a graphene thin film deposited on the gate region of an extended-gate electric double-layer field-effect transistor (EGEDL-FET). This unique combination of materials and device structure enables superior glucose sensing performance. Ni nanowires were deposited on the surface of the extended gate region of the EGEDL-FET, where high quality monolayer graphene grown by chemical vapor deposition (CVD) had been previously transferred. The Ni nanowires provide a high surface area and excellent catalytic activity for non-enzymatic glucose oxidation. Meanwhile, the graphene thin film enhances the conductivity of the sensing interface due to the matching of work functions between the Ni nanowires and the graphene. The bimetal gate-electrolyte interface with a spacing of 65 μm forms an electric double layer that effectively avoids ion shielding due to its dimension being smaller than the Debye length. This configuration significantly amplifies the electrical signal, thereby enhancing the sensor's sensitivity. The fabricated EGEDL-FET glucose sensor demonstrates a wide linear range from 0.05 mM to 5 mM, high sensitivity of 1043 mA μM−1 cm−2, and a low detection limit of 51 nM. The synergistic effect of the Ni nanowires, graphene film, and EGEDL-FET configuration results in a highly sensitive non-enzymatic glucose sensor with excellent selectivity in glucose alkaline solutions containing both chloride ions and potassium ions. These experimental results represent a promising advancement for glucose monitoring systems, offering improved performance and reliability.
format Article
id doaj-art-0f194fafed064675be21d94ce166a101
institution Kabale University
issn 2405-8440
language English
publishDate 2025-01-01
publisher Elsevier
record_format Article
series Heliyon
spelling doaj-art-0f194fafed064675be21d94ce166a1012025-02-02T05:28:24ZengElsevierHeliyon2405-84402025-01-01112e41857Highly sensitive non-enzymatic glucose sensing using Ni nanowires and graphene thin film on the gate area of extended gate electric double-layer field-effect transistorSheng-Chun Hung0Department of Electrical Engineering, Feng Chia University, Taichung, 407802, TaiwanThis study presents an innovative glucose detection platform, featuring a highly sensitive, non-enzymatic glucose sensor. The sensor integrates nickel nanowires and a graphene thin film deposited on the gate region of an extended-gate electric double-layer field-effect transistor (EGEDL-FET). This unique combination of materials and device structure enables superior glucose sensing performance. Ni nanowires were deposited on the surface of the extended gate region of the EGEDL-FET, where high quality monolayer graphene grown by chemical vapor deposition (CVD) had been previously transferred. The Ni nanowires provide a high surface area and excellent catalytic activity for non-enzymatic glucose oxidation. Meanwhile, the graphene thin film enhances the conductivity of the sensing interface due to the matching of work functions between the Ni nanowires and the graphene. The bimetal gate-electrolyte interface with a spacing of 65 μm forms an electric double layer that effectively avoids ion shielding due to its dimension being smaller than the Debye length. This configuration significantly amplifies the electrical signal, thereby enhancing the sensor's sensitivity. The fabricated EGEDL-FET glucose sensor demonstrates a wide linear range from 0.05 mM to 5 mM, high sensitivity of 1043 mA μM−1 cm−2, and a low detection limit of 51 nM. The synergistic effect of the Ni nanowires, graphene film, and EGEDL-FET configuration results in a highly sensitive non-enzymatic glucose sensor with excellent selectivity in glucose alkaline solutions containing both chloride ions and potassium ions. These experimental results represent a promising advancement for glucose monitoring systems, offering improved performance and reliability.http://www.sciencedirect.com/science/article/pii/S2405844025002373Glucose sensorsNi nanowiresGrapheneElectric double layer (EDL)Field-effect transistors (FETs)
spellingShingle Sheng-Chun Hung
Highly sensitive non-enzymatic glucose sensing using Ni nanowires and graphene thin film on the gate area of extended gate electric double-layer field-effect transistor
Heliyon
Glucose sensors
Ni nanowires
Graphene
Electric double layer (EDL)
Field-effect transistors (FETs)
title Highly sensitive non-enzymatic glucose sensing using Ni nanowires and graphene thin film on the gate area of extended gate electric double-layer field-effect transistor
title_full Highly sensitive non-enzymatic glucose sensing using Ni nanowires and graphene thin film on the gate area of extended gate electric double-layer field-effect transistor
title_fullStr Highly sensitive non-enzymatic glucose sensing using Ni nanowires and graphene thin film on the gate area of extended gate electric double-layer field-effect transistor
title_full_unstemmed Highly sensitive non-enzymatic glucose sensing using Ni nanowires and graphene thin film on the gate area of extended gate electric double-layer field-effect transistor
title_short Highly sensitive non-enzymatic glucose sensing using Ni nanowires and graphene thin film on the gate area of extended gate electric double-layer field-effect transistor
title_sort highly sensitive non enzymatic glucose sensing using ni nanowires and graphene thin film on the gate area of extended gate electric double layer field effect transistor
topic Glucose sensors
Ni nanowires
Graphene
Electric double layer (EDL)
Field-effect transistors (FETs)
url http://www.sciencedirect.com/science/article/pii/S2405844025002373
work_keys_str_mv AT shengchunhung highlysensitivenonenzymaticglucosesensingusingninanowiresandgraphenethinfilmonthegateareaofextendedgateelectricdoublelayerfieldeffecttransistor