A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element Study

Objectives. The aim of this study was to analyse by means of FEA the influence of 5 custom RAI designs on stress distribution of peri-implant bone and to evaluate the impact on microdisplacement for a specific patient case. Materials and Methods. A 3D surface model of a RAI for the upper right canin...

Full description

Saved in:
Bibliographic Details
Main Authors: David Anssari Moin, Bassam Hassan, Daniel Wismeijer
Format: Article
Language:English
Published: Wiley 2016-01-01
Series:International Journal of Dentistry
Online Access:http://dx.doi.org/10.1155/2016/8242535
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832566660133814272
author David Anssari Moin
Bassam Hassan
Daniel Wismeijer
author_facet David Anssari Moin
Bassam Hassan
Daniel Wismeijer
author_sort David Anssari Moin
collection DOAJ
description Objectives. The aim of this study was to analyse by means of FEA the influence of 5 custom RAI designs on stress distribution of peri-implant bone and to evaluate the impact on microdisplacement for a specific patient case. Materials and Methods. A 3D surface model of a RAI for the upper right canine was constructed from the cone beam computed tomography data of one patient. Subsequently, five (targeted) press-fit design modification FE models with five congruent bone models were designed: “Standard,” “Prism,” “Fins,” “Plug,” and “Bulbs,” respectively. Preprocessor software was applied to mesh the models. Two loads were applied: an oblique force (300 N) and a vertical force (150 N). Analysis was performed to evaluate stress distributions and deformed contact separation at the peri-implant region. Results. The lowest von Mises stress levels were numerically observed for the Plug design. The lowest levels of contact separation were measured in the Fins model followed by the Bulbs design. Conclusions. Within the limitations of the applied methodology, adding targeted press-fit geometry to the RAI standard design will have a positive effect on stress distribution, lower concentration of bone stress, and will provide a better primary stability for this patient specific case.
format Article
id doaj-art-08e02eb30aaa416db6943818a8c56d69
institution Kabale University
issn 1687-8728
1687-8736
language English
publishDate 2016-01-01
publisher Wiley
record_format Article
series International Journal of Dentistry
spelling doaj-art-08e02eb30aaa416db6943818a8c56d692025-02-03T01:03:29ZengWileyInternational Journal of Dentistry1687-87281687-87362016-01-01201610.1155/2016/82425358242535A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element StudyDavid Anssari Moin0Bassam Hassan1Daniel Wismeijer2Department of Oral Function and Restorative Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), Research Institute MOVE, 1081 LA Amsterdam, NetherlandsDepartment of Oral Function and Restorative Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), Research Institute MOVE, 1081 LA Amsterdam, NetherlandsDepartment of Oral Function and Restorative Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), Research Institute MOVE, 1081 LA Amsterdam, NetherlandsObjectives. The aim of this study was to analyse by means of FEA the influence of 5 custom RAI designs on stress distribution of peri-implant bone and to evaluate the impact on microdisplacement for a specific patient case. Materials and Methods. A 3D surface model of a RAI for the upper right canine was constructed from the cone beam computed tomography data of one patient. Subsequently, five (targeted) press-fit design modification FE models with five congruent bone models were designed: “Standard,” “Prism,” “Fins,” “Plug,” and “Bulbs,” respectively. Preprocessor software was applied to mesh the models. Two loads were applied: an oblique force (300 N) and a vertical force (150 N). Analysis was performed to evaluate stress distributions and deformed contact separation at the peri-implant region. Results. The lowest von Mises stress levels were numerically observed for the Plug design. The lowest levels of contact separation were measured in the Fins model followed by the Bulbs design. Conclusions. Within the limitations of the applied methodology, adding targeted press-fit geometry to the RAI standard design will have a positive effect on stress distribution, lower concentration of bone stress, and will provide a better primary stability for this patient specific case.http://dx.doi.org/10.1155/2016/8242535
spellingShingle David Anssari Moin
Bassam Hassan
Daniel Wismeijer
A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element Study
International Journal of Dentistry
title A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element Study
title_full A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element Study
title_fullStr A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element Study
title_full_unstemmed A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element Study
title_short A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element Study
title_sort patient specific biomechanical analysis of custom root analogue implant designs on alveolar bone stress a finite element study
url http://dx.doi.org/10.1155/2016/8242535
work_keys_str_mv AT davidanssarimoin apatientspecificbiomechanicalanalysisofcustomrootanalogueimplantdesignsonalveolarbonestressafiniteelementstudy
AT bassamhassan apatientspecificbiomechanicalanalysisofcustomrootanalogueimplantdesignsonalveolarbonestressafiniteelementstudy
AT danielwismeijer apatientspecificbiomechanicalanalysisofcustomrootanalogueimplantdesignsonalveolarbonestressafiniteelementstudy
AT davidanssarimoin patientspecificbiomechanicalanalysisofcustomrootanalogueimplantdesignsonalveolarbonestressafiniteelementstudy
AT bassamhassan patientspecificbiomechanicalanalysisofcustomrootanalogueimplantdesignsonalveolarbonestressafiniteelementstudy
AT danielwismeijer patientspecificbiomechanicalanalysisofcustomrootanalogueimplantdesignsonalveolarbonestressafiniteelementstudy