Test of Cable Products in Respect of Thermal and Dynamic Stability

The paper considers conditions for selection of  power supply of the unit which is used for testing samples of cable products by thermal and dynamic stability currents. It has been shown that while conducting testing by thermal and dynamic stability currents at nominal cable voltage it is more justi...

Full description

Saved in:
Bibliographic Details
Main Authors: M. A. Korotkevich, I. V. Oleksiouk
Format: Article
Language:Russian
Published: Belarusian National Technical University 2010-02-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Online Access:https://energy.bntu.by/jour/article/view/445
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832543683641081856
author M. A. Korotkevich
I. V. Oleksiouk
author_facet M. A. Korotkevich
I. V. Oleksiouk
author_sort M. A. Korotkevich
collection DOAJ
description The paper considers conditions for selection of  power supply of the unit which is used for testing samples of cable products by thermal and dynamic stability currents. It has been shown that while conducting testing by thermal and dynamic stability currents at nominal cable voltage it is more justifiable to use a percussive energy accumulator, and in the case when the voltage is low an inductive energy accumulator is used.
format Article
id doaj-art-080a3f2827524529a2a0bd9ecfa4975e
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2010-02-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-080a3f2827524529a2a0bd9ecfa4975e2025-02-03T11:34:19ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412010-02-01012532438Test of Cable Products in Respect of Thermal and Dynamic StabilityM. A. Korotkevich0I. V. Oleksiouk1Belarusian National Technical UniversityBelarusian National Technical UniversityThe paper considers conditions for selection of  power supply of the unit which is used for testing samples of cable products by thermal and dynamic stability currents. It has been shown that while conducting testing by thermal and dynamic stability currents at nominal cable voltage it is more justifiable to use a percussive energy accumulator, and in the case when the voltage is low an inductive energy accumulator is used.https://energy.bntu.by/jour/article/view/445
spellingShingle M. A. Korotkevich
I. V. Oleksiouk
Test of Cable Products in Respect of Thermal and Dynamic Stability
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
title Test of Cable Products in Respect of Thermal and Dynamic Stability
title_full Test of Cable Products in Respect of Thermal and Dynamic Stability
title_fullStr Test of Cable Products in Respect of Thermal and Dynamic Stability
title_full_unstemmed Test of Cable Products in Respect of Thermal and Dynamic Stability
title_short Test of Cable Products in Respect of Thermal and Dynamic Stability
title_sort test of cable products in respect of thermal and dynamic stability
url https://energy.bntu.by/jour/article/view/445
work_keys_str_mv AT makorotkevich testofcableproductsinrespectofthermalanddynamicstability
AT ivoleksiouk testofcableproductsinrespectofthermalanddynamicstability