Test of Cable Products in Respect of Thermal and Dynamic Stability
The paper considers conditions for selection of power supply of the unit which is used for testing samples of cable products by thermal and dynamic stability currents. It has been shown that while conducting testing by thermal and dynamic stability currents at nominal cable voltage it is more justi...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Belarusian National Technical University
2010-02-01
|
Series: | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
Online Access: | https://energy.bntu.by/jour/article/view/445 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832543683641081856 |
---|---|
author | M. A. Korotkevich I. V. Oleksiouk |
author_facet | M. A. Korotkevich I. V. Oleksiouk |
author_sort | M. A. Korotkevich |
collection | DOAJ |
description | The paper considers conditions for selection of power supply of the unit which is used for testing samples of cable products by thermal and dynamic stability currents. It has been shown that while conducting testing by thermal and dynamic stability currents at nominal cable voltage it is more justifiable to use a percussive energy accumulator, and in the case when the voltage is low an inductive energy accumulator is used. |
format | Article |
id | doaj-art-080a3f2827524529a2a0bd9ecfa4975e |
institution | Kabale University |
issn | 1029-7448 2414-0341 |
language | Russian |
publishDate | 2010-02-01 |
publisher | Belarusian National Technical University |
record_format | Article |
series | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
spelling | doaj-art-080a3f2827524529a2a0bd9ecfa4975e2025-02-03T11:34:19ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412010-02-01012532438Test of Cable Products in Respect of Thermal and Dynamic StabilityM. A. Korotkevich0I. V. Oleksiouk1Belarusian National Technical UniversityBelarusian National Technical UniversityThe paper considers conditions for selection of power supply of the unit which is used for testing samples of cable products by thermal and dynamic stability currents. It has been shown that while conducting testing by thermal and dynamic stability currents at nominal cable voltage it is more justifiable to use a percussive energy accumulator, and in the case when the voltage is low an inductive energy accumulator is used.https://energy.bntu.by/jour/article/view/445 |
spellingShingle | M. A. Korotkevich I. V. Oleksiouk Test of Cable Products in Respect of Thermal and Dynamic Stability Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
title | Test of Cable Products in Respect of Thermal and Dynamic Stability |
title_full | Test of Cable Products in Respect of Thermal and Dynamic Stability |
title_fullStr | Test of Cable Products in Respect of Thermal and Dynamic Stability |
title_full_unstemmed | Test of Cable Products in Respect of Thermal and Dynamic Stability |
title_short | Test of Cable Products in Respect of Thermal and Dynamic Stability |
title_sort | test of cable products in respect of thermal and dynamic stability |
url | https://energy.bntu.by/jour/article/view/445 |
work_keys_str_mv | AT makorotkevich testofcableproductsinrespectofthermalanddynamicstability AT ivoleksiouk testofcableproductsinrespectofthermalanddynamicstability |