Determination of Permissible Short-Time Emergency Overloading of Turbo-Generators and Synchronous Compensators

The paper shows that failure to take into account variable ratio of short-time emergency overloading of turbo-generators (synchronous compensators) that can lead to underestimation of overloading capacity or impermissible insulation over-heating.A method has been developed for determination of permi...

Full description

Saved in:
Bibliographic Details
Main Authors: V. A. Anischenko, V. A. Adamtsevich
Format: Article
Language:Russian
Published: Belarusian National Technical University 2011-08-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Online Access:https://energy.bntu.by/jour/article/view/269
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832557210422476800
author V. A. Anischenko
V. A. Adamtsevich
author_facet V. A. Anischenko
V. A. Adamtsevich
author_sort V. A. Anischenko
collection DOAJ
description The paper shows that failure to take into account variable ratio of short-time emergency overloading of turbo-generators (synchronous compensators) that can lead to underestimation of overloading capacity or impermissible insulation over-heating.A method has been developed for determination of permissible duration of short-time emergency over-loading that takes into account changes of over-loading ratio in case of a failure.
format Article
id doaj-art-04aa06ecba5c45a7b0ad41cbc3a86283
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2011-08-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-04aa06ecba5c45a7b0ad41cbc3a862832025-02-03T05:35:49ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412011-08-010410.21122/1029-7448-2011-0-4-92-102263Determination of Permissible Short-Time Emergency Overloading of Turbo-Generators and Synchronous CompensatorsV. A. Anischenko0V. A. Adamtsevich1Belarusian National Technical UniversityBelarusian National Technical UniversityThe paper shows that failure to take into account variable ratio of short-time emergency overloading of turbo-generators (synchronous compensators) that can lead to underestimation of overloading capacity or impermissible insulation over-heating.A method has been developed for determination of permissible duration of short-time emergency over-loading that takes into account changes of over-loading ratio in case of a failure.https://energy.bntu.by/jour/article/view/269
spellingShingle V. A. Anischenko
V. A. Adamtsevich
Determination of Permissible Short-Time Emergency Overloading of Turbo-Generators and Synchronous Compensators
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
title Determination of Permissible Short-Time Emergency Overloading of Turbo-Generators and Synchronous Compensators
title_full Determination of Permissible Short-Time Emergency Overloading of Turbo-Generators and Synchronous Compensators
title_fullStr Determination of Permissible Short-Time Emergency Overloading of Turbo-Generators and Synchronous Compensators
title_full_unstemmed Determination of Permissible Short-Time Emergency Overloading of Turbo-Generators and Synchronous Compensators
title_short Determination of Permissible Short-Time Emergency Overloading of Turbo-Generators and Synchronous Compensators
title_sort determination of permissible short time emergency overloading of turbo generators and synchronous compensators
url https://energy.bntu.by/jour/article/view/269
work_keys_str_mv AT vaanischenko determinationofpermissibleshorttimeemergencyoverloadingofturbogeneratorsandsynchronouscompensators
AT vaadamtsevich determinationofpermissibleshorttimeemergencyoverloadingofturbogeneratorsandsynchronouscompensators