Isotropic Broadband E-Field Probe
An E-field probe has been developed for EMC immunity tests performed in closed space. The leads are flexible resistive transmission lines. Their influence on the field distribution is negligible. The probe has an isotropic reception from 100 MHz to 18 GHz; the sensitivity is in the 3 V/m–10 V/m rang...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2008-01-01
|
Series: | Active and Passive Electronic Components |
Online Access: | http://dx.doi.org/10.1155/2008/816969 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832553236699021312 |
---|---|
author | Béla Szentpáli István Réti Ferenc B. Molnár János Farkasvölgyi Károly Kazi Zoltán Mirk Aurél Sonkoly Zoltán Horváth |
author_facet | Béla Szentpáli István Réti Ferenc B. Molnár János Farkasvölgyi Károly Kazi Zoltán Mirk Aurél Sonkoly Zoltán Horváth |
author_sort | Béla Szentpáli |
collection | DOAJ |
description | An E-field probe has been developed for EMC immunity tests performed in closed space. The leads are flexible resistive transmission lines. Their influence on the field distribution is negligible. The probe has an isotropic reception from 100 MHz to 18 GHz; the sensitivity is in the 3 V/m–10 V/m range. The device is an accessory of the EMC test chamber. The readout of the field magnitude is carried out by personal computer, which fulfils also the required corrections of the raw data. |
format | Article |
id | doaj-art-0401dc8b2a0c49a798fd31a383e925b6 |
institution | Kabale University |
issn | 0882-7516 1563-5031 |
language | English |
publishDate | 2008-01-01 |
publisher | Wiley |
record_format | Article |
series | Active and Passive Electronic Components |
spelling | doaj-art-0401dc8b2a0c49a798fd31a383e925b62025-02-03T05:54:30ZengWileyActive and Passive Electronic Components0882-75161563-50312008-01-01200810.1155/2008/816969816969Isotropic Broadband E-Field ProbeBéla Szentpáli0István Réti1Ferenc B. Molnár2János Farkasvölgyi3Károly Kazi4Zoltán Mirk5Aurél Sonkoly6Zoltán Horváth7Research Institute for Technical Physics and Materials Science, P.O. Box 49, H-1525 Budapest, HungaryResearch Institute for Technical Physics and Materials Science, P.O. Box 49, H-1525 Budapest, HungaryResearch Institute for Technical Physics and Materials Science, P.O. Box 49, H-1525 Budapest, HungaryBonn Hungary Electronics Ltd., P.O. Box 164, 1325 Budapest, HungaryBonn Hungary Electronics Ltd., P.O. Box 164, 1325 Budapest, HungaryBonn Hungary Electronics Ltd., P.O. Box 164, 1325 Budapest, HungaryLINEARLAB Ltd., Budapest Fóti út 56, 1047 Budapest, HungaryLINEARLAB Ltd., Budapest Fóti út 56, 1047 Budapest, HungaryAn E-field probe has been developed for EMC immunity tests performed in closed space. The leads are flexible resistive transmission lines. Their influence on the field distribution is negligible. The probe has an isotropic reception from 100 MHz to 18 GHz; the sensitivity is in the 3 V/m–10 V/m range. The device is an accessory of the EMC test chamber. The readout of the field magnitude is carried out by personal computer, which fulfils also the required corrections of the raw data.http://dx.doi.org/10.1155/2008/816969 |
spellingShingle | Béla Szentpáli István Réti Ferenc B. Molnár János Farkasvölgyi Károly Kazi Zoltán Mirk Aurél Sonkoly Zoltán Horváth Isotropic Broadband E-Field Probe Active and Passive Electronic Components |
title | Isotropic Broadband E-Field Probe |
title_full | Isotropic Broadband E-Field Probe |
title_fullStr | Isotropic Broadband E-Field Probe |
title_full_unstemmed | Isotropic Broadband E-Field Probe |
title_short | Isotropic Broadband E-Field Probe |
title_sort | isotropic broadband e field probe |
url | http://dx.doi.org/10.1155/2008/816969 |
work_keys_str_mv | AT belaszentpali isotropicbroadbandefieldprobe AT istvanreti isotropicbroadbandefieldprobe AT ferencbmolnar isotropicbroadbandefieldprobe AT janosfarkasvolgyi isotropicbroadbandefieldprobe AT karolykazi isotropicbroadbandefieldprobe AT zoltanmirk isotropicbroadbandefieldprobe AT aurelsonkoly isotropicbroadbandefieldprobe AT zoltanhorvath isotropicbroadbandefieldprobe |