ANALYSIS OF ASIR VARIATION EFFECT TO SNR ON UNENHANCED ABDOMINAL CT SCAN IN UROLITHIASIS

Background: Adaptive Statistical Iterative Reconstruction (ASIR) reconstruction in unenhanced abdominal CT scan reduce the radiation dose from 11.6 mSv to 2.07 mSv. However, the decrease in dose is accompanied by a decrease in image quality. Signal to Noise Ratio (SNR) is one of image quality parame...

Full description

Saved in:
Bibliographic Details
Main Authors: Rizki Aditiya Pratama Putra, Paulus Rahardjo, Pramono Pramono
Format: Article
Language:English
Published: Universitas Airlangga 2020-11-01
Series:Journal of Vocational Health Studies
Subjects:
Online Access:https://e-journal.unair.ac.id/JVHS/article/view/22467
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832573260918685696
author Rizki Aditiya Pratama Putra
Paulus Rahardjo
Pramono Pramono
author_facet Rizki Aditiya Pratama Putra
Paulus Rahardjo
Pramono Pramono
author_sort Rizki Aditiya Pratama Putra
collection DOAJ
description Background: Adaptive Statistical Iterative Reconstruction (ASIR) reconstruction in unenhanced abdominal CT scan reduce the radiation dose from 11.6 mSv to 2.07 mSv. However, the decrease in dose is accompanied by a decrease in image quality. Signal to Noise Ratio (SNR) is one of image quality parameters. Purpose: This study aims to determine the effect of the ASIR method on the optimal Signal to Noise Ratio (SNR) value in unenhanced abdominal CT of urolithiasis in clinical data. Method: 27 samples collected and the SNR was measured on the ASIR reconstruction results at the level of 40%, 50%, 60% by placing the ROI  in organ structures with different densities. Result: The results of this study indicate that the ASIR method has a significant effect on the SNR value. Based on the linear regression test, the value was 0.005 ( p< 0.05) and only had an effect of 9.5% on SNR. Conclusion: It can be concluded that the ASIR method affects the optimal SNR value for unenhanced abdominal CT on urolithiasis. The ASIR 60% level was recommended.
format Article
id doaj-art-026bb4545d3b4079a20ef88095d096a9
institution Kabale University
issn 2580-7161
2580-717X
language English
publishDate 2020-11-01
publisher Universitas Airlangga
record_format Article
series Journal of Vocational Health Studies
spelling doaj-art-026bb4545d3b4079a20ef88095d096a92025-02-02T05:13:44ZengUniversitas AirlanggaJournal of Vocational Health Studies2580-71612580-717X2020-11-0142788210.20473/jvhs.V4.I2.2020.78-8211209ANALYSIS OF ASIR VARIATION EFFECT TO SNR ON UNENHANCED ABDOMINAL CT SCAN IN UROLITHIASISRizki Aditiya Pratama Putra0Paulus Rahardjo1Pramono Pramono2Departement of Health, Faculty of Vocational Studies, Universitas Airlangga, Surabaya - IndonesiaDepartment of Radiology, Faculty of Medicine, Universitas Airlangga, Surabaya - IndonesiaRadiodiagnostic Division, Dr.Soetomo General Hospital, Surabaya – IndonesiaBackground: Adaptive Statistical Iterative Reconstruction (ASIR) reconstruction in unenhanced abdominal CT scan reduce the radiation dose from 11.6 mSv to 2.07 mSv. However, the decrease in dose is accompanied by a decrease in image quality. Signal to Noise Ratio (SNR) is one of image quality parameters. Purpose: This study aims to determine the effect of the ASIR method on the optimal Signal to Noise Ratio (SNR) value in unenhanced abdominal CT of urolithiasis in clinical data. Method: 27 samples collected and the SNR was measured on the ASIR reconstruction results at the level of 40%, 50%, 60% by placing the ROI  in organ structures with different densities. Result: The results of this study indicate that the ASIR method has a significant effect on the SNR value. Based on the linear regression test, the value was 0.005 ( p< 0.05) and only had an effect of 9.5% on SNR. Conclusion: It can be concluded that the ASIR method affects the optimal SNR value for unenhanced abdominal CT on urolithiasis. The ASIR 60% level was recommended.https://e-journal.unair.ac.id/JVHS/article/view/22467adaptive statistical iterative reconstruction (asir)signal to noise ratio (snr)unenhanced abominal ct scanurolithiasis
spellingShingle Rizki Aditiya Pratama Putra
Paulus Rahardjo
Pramono Pramono
ANALYSIS OF ASIR VARIATION EFFECT TO SNR ON UNENHANCED ABDOMINAL CT SCAN IN UROLITHIASIS
Journal of Vocational Health Studies
adaptive statistical iterative reconstruction (asir)
signal to noise ratio (snr)
unenhanced abominal ct scan
urolithiasis
title ANALYSIS OF ASIR VARIATION EFFECT TO SNR ON UNENHANCED ABDOMINAL CT SCAN IN UROLITHIASIS
title_full ANALYSIS OF ASIR VARIATION EFFECT TO SNR ON UNENHANCED ABDOMINAL CT SCAN IN UROLITHIASIS
title_fullStr ANALYSIS OF ASIR VARIATION EFFECT TO SNR ON UNENHANCED ABDOMINAL CT SCAN IN UROLITHIASIS
title_full_unstemmed ANALYSIS OF ASIR VARIATION EFFECT TO SNR ON UNENHANCED ABDOMINAL CT SCAN IN UROLITHIASIS
title_short ANALYSIS OF ASIR VARIATION EFFECT TO SNR ON UNENHANCED ABDOMINAL CT SCAN IN UROLITHIASIS
title_sort analysis of asir variation effect to snr on unenhanced abdominal ct scan in urolithiasis
topic adaptive statistical iterative reconstruction (asir)
signal to noise ratio (snr)
unenhanced abominal ct scan
urolithiasis
url https://e-journal.unair.ac.id/JVHS/article/view/22467
work_keys_str_mv AT rizkiaditiyapratamaputra analysisofasirvariationeffecttosnronunenhancedabdominalctscaninurolithiasis
AT paulusrahardjo analysisofasirvariationeffecttosnronunenhancedabdominalctscaninurolithiasis
AT pramonopramono analysisofasirvariationeffecttosnronunenhancedabdominalctscaninurolithiasis