Influences of Flow Attack Angles and Flow Directions on Heat Transfer Rate, Pressure Loss, and Thermal Performance in Heat Exchanger Tube with V-Wavy Surface
Numerical investigations on flow and heat transfer characteristics in the heat exchanger tube with the V-wavy surface are presented. The finite volume method with the SIMPLE algorithm is selected to solve the present problem. The effects of flow attack angles (α = 15°, 20°, 25°, 30°, 35°, 40°, 45°,...
Saved in:
Main Authors: | Amnart Boonloi, Withada Jedsadaratanachai |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2018-01-01
|
Series: | Modelling and Simulation in Engineering |
Online Access: | http://dx.doi.org/10.1155/2018/5848290 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Effect of Flow Attack Angle for V-Wavy Plate on Flow and Heat Transfer in a Square Channel Heat Exchanger
by: Amnart Boonloi, et al.
Published: (2018-01-01) -
Numerical Study on Flow and Heat Transfer Mechanisms in the Heat Exchanger Channel with V-Orifice at Various Blockage Ratios, Gap Spacing Ratios, and Flow Directions
by: Amnart Boonloi, et al.
Published: (2019-01-01) -
Numerical Study of Airflows, Thermal Structures, and Performance in a Circular Tube Heat Exchanger with Staggered Combined Vortex Producers
by: Amnart Boonloi, et al.
Published: (2024-01-01) -
Heat Transfer Potentiality and Flow Behavior in a Square Duct Fitted with Double-Inclined Baffles: A Numerical Analysis
by: Amnart Boonloi, et al.
Published: (2021-01-01) -
Effects of Baffle Height and Baffle Location on Heat Transfer and Flow Profiles in a Baffled Duct: A CFD Analysis
by: Amnart Boonloi, et al.
Published: (2022-01-01)