Prediction of Seven Artificial Intelligence-Based Intraocular Lens Power Calculation Formulas in Medium-Long Caucasian Eyes
<b>Purpose:</b> To compare the accuracy of seven artificial intelligence (AI)-based intraocular lens (IOL) power calculation formulas in medium-long Caucasian eyes regarding the root-mean-square absolute error (RMSAE), the median absolute error (MedAE) and the percentage of eyes with a p...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2025-01-01
|
Series: | Life |
Subjects: | |
Online Access: | https://www.mdpi.com/2075-1729/15/1/45 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832588105487482880 |
---|---|
author | Wiktor Stopyra Oleksiy Voytsekhivskyy Andrzej Grzybowski |
author_facet | Wiktor Stopyra Oleksiy Voytsekhivskyy Andrzej Grzybowski |
author_sort | Wiktor Stopyra |
collection | DOAJ |
description | <b>Purpose:</b> To compare the accuracy of seven artificial intelligence (AI)-based intraocular lens (IOL) power calculation formulas in medium-long Caucasian eyes regarding the root-mean-square absolute error (RMSAE), the median absolute error (MedAE) and the percentage of eyes with a prediction error (PE) within ±0.5 D. <b>Methods:</b> Data on Caucasian patients who underwent uneventful phacoemulsification between May 2018 and September 2023 in MW-Med Eye Center, Krakow, Poland and Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Kyiv, Ukraine were reviewed. Inclusion criteria, i.e., complete biometric and refractive data, were applied. Exclusion criteria were as follows: intraoperative or postoperative complications, previous eye surgery or corneal diseases, postoperative BCVA less than 0.8, and corneal astigmatism greater than 2.0 D. Prior to phacoemulsification, IOL power was computed using SRK/T, Holladay1, Haigis, Holladay 2, and Hoffer Q. The refraction was measured three months after cataract surgery. Post-surgery intraocular lens calculations for Hill-RBF 3.0, Kane, PEARL-DGS, Ladas Super Formula AI (LSF AI), Hoffer QST, Karmona, and Nallasamy were performed. RMSAE, MedAE, and the percentage of eyes with a PE within ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 were counted. <b>Results:</b> Two hundred fourteen eyes with axial lengths ranging from 24.50 mm to 25.97 mm were tested. The Hill-RBF 3.0 formula yielded the lowest RMSAE (0.368), just before Pearl-DGS (0.374) and Hoffer QST (0.378). The lowest MedAE was achieved by Hill-RBF 3.0 (0.200), the second-lowest by LSF AI (0.210), and the third-lowest by Kane (0.228). The highest percentage of eyes with a PE within ±0.50 D was obtained by Hill-RBF 3.0, LSF AI, and Pearl-DGS (86.45%, 85.51%, and 85.05%, respectively). <b>Conclusions:</b> The Hill-RBF 3.0 formula provided highly accurate outcomes in medium-long eyes. All studied AI-based formulas yielded good results in IOL power calculation. |
format | Article |
id | doaj-art-0047bbca65ac4beeab9361aa034ff8b5 |
institution | Kabale University |
issn | 2075-1729 |
language | English |
publishDate | 2025-01-01 |
publisher | MDPI AG |
record_format | Article |
series | Life |
spelling | doaj-art-0047bbca65ac4beeab9361aa034ff8b52025-01-24T13:38:34ZengMDPI AGLife2075-17292025-01-011514510.3390/life15010045Prediction of Seven Artificial Intelligence-Based Intraocular Lens Power Calculation Formulas in Medium-Long Caucasian EyesWiktor Stopyra0Oleksiy Voytsekhivskyy1Andrzej Grzybowski2MW-Med Eye Centre, 31-416 Krakow, PolandKyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, 03680 Kyiv, UkraineInstitute for Research in Ophthalmology, Foundation for Ophthalmology Development, 61-553 Poznan, Poland<b>Purpose:</b> To compare the accuracy of seven artificial intelligence (AI)-based intraocular lens (IOL) power calculation formulas in medium-long Caucasian eyes regarding the root-mean-square absolute error (RMSAE), the median absolute error (MedAE) and the percentage of eyes with a prediction error (PE) within ±0.5 D. <b>Methods:</b> Data on Caucasian patients who underwent uneventful phacoemulsification between May 2018 and September 2023 in MW-Med Eye Center, Krakow, Poland and Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Kyiv, Ukraine were reviewed. Inclusion criteria, i.e., complete biometric and refractive data, were applied. Exclusion criteria were as follows: intraoperative or postoperative complications, previous eye surgery or corneal diseases, postoperative BCVA less than 0.8, and corneal astigmatism greater than 2.0 D. Prior to phacoemulsification, IOL power was computed using SRK/T, Holladay1, Haigis, Holladay 2, and Hoffer Q. The refraction was measured three months after cataract surgery. Post-surgery intraocular lens calculations for Hill-RBF 3.0, Kane, PEARL-DGS, Ladas Super Formula AI (LSF AI), Hoffer QST, Karmona, and Nallasamy were performed. RMSAE, MedAE, and the percentage of eyes with a PE within ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 were counted. <b>Results:</b> Two hundred fourteen eyes with axial lengths ranging from 24.50 mm to 25.97 mm were tested. The Hill-RBF 3.0 formula yielded the lowest RMSAE (0.368), just before Pearl-DGS (0.374) and Hoffer QST (0.378). The lowest MedAE was achieved by Hill-RBF 3.0 (0.200), the second-lowest by LSF AI (0.210), and the third-lowest by Kane (0.228). The highest percentage of eyes with a PE within ±0.50 D was obtained by Hill-RBF 3.0, LSF AI, and Pearl-DGS (86.45%, 85.51%, and 85.05%, respectively). <b>Conclusions:</b> The Hill-RBF 3.0 formula provided highly accurate outcomes in medium-long eyes. All studied AI-based formulas yielded good results in IOL power calculation.https://www.mdpi.com/2075-1729/15/1/45phacoemulsificationmedium-long eyesintraocular lensesartificial intelligenceHill-RBF formula |
spellingShingle | Wiktor Stopyra Oleksiy Voytsekhivskyy Andrzej Grzybowski Prediction of Seven Artificial Intelligence-Based Intraocular Lens Power Calculation Formulas in Medium-Long Caucasian Eyes Life phacoemulsification medium-long eyes intraocular lenses artificial intelligence Hill-RBF formula |
title | Prediction of Seven Artificial Intelligence-Based Intraocular Lens Power Calculation Formulas in Medium-Long Caucasian Eyes |
title_full | Prediction of Seven Artificial Intelligence-Based Intraocular Lens Power Calculation Formulas in Medium-Long Caucasian Eyes |
title_fullStr | Prediction of Seven Artificial Intelligence-Based Intraocular Lens Power Calculation Formulas in Medium-Long Caucasian Eyes |
title_full_unstemmed | Prediction of Seven Artificial Intelligence-Based Intraocular Lens Power Calculation Formulas in Medium-Long Caucasian Eyes |
title_short | Prediction of Seven Artificial Intelligence-Based Intraocular Lens Power Calculation Formulas in Medium-Long Caucasian Eyes |
title_sort | prediction of seven artificial intelligence based intraocular lens power calculation formulas in medium long caucasian eyes |
topic | phacoemulsification medium-long eyes intraocular lenses artificial intelligence Hill-RBF formula |
url | https://www.mdpi.com/2075-1729/15/1/45 |
work_keys_str_mv | AT wiktorstopyra predictionofsevenartificialintelligencebasedintraocularlenspowercalculationformulasinmediumlongcaucasianeyes AT oleksiyvoytsekhivskyy predictionofsevenartificialintelligencebasedintraocularlenspowercalculationformulasinmediumlongcaucasianeyes AT andrzejgrzybowski predictionofsevenartificialintelligencebasedintraocularlenspowercalculationformulasinmediumlongcaucasianeyes |